StorEdge L25 L100 common error codes and part numbers

Tape Alert Flag: 46 – recycle power to fix
Tape Alert Flag: 37 – replace drive
Tape Alert Flag: 38 – – replace drive – or – upgrade firmware – or – replace system board

– Fault System Code: 4401 :Frame 1: Door 1 open (left door)

– Fault System Code: 4405 :Frame 1: Door 1 closed (left door)

– Fault System Code: 4405 :Frame 1: Door 1 closed (left door)

380-0892 LTO Gen 2 Low Voltage Differential (LVD) SCSI Drive for L25/L100
380-1196 LTO Gen 3 Low Voltage Differential (LVD) SCSI Drive for L25/L100
380-0811 LTO Gen 1 Low Voltage Differential (LVD) SCSI Drive for L25/L100
380-0682 SDLT 220 High Voltage Differential (HVD) Tape Drive
380-0820 SDLT320 Low Voltage Differential (LVD) Tape Drive
380-0980 SDLT600 Low Voltage Differential (LVD) drive

StorEdge L9 timeout

reset the drivers

#devfsadm -v

Delete the jukebox using

#/usr/bin/nsr/nwadmin

Re-configure the jukebox with jbconfig

#/usr/sbin/nsr/jbconfig
1) Configure an AlphaStor/SmartMedia Jukebox.
2) Configure an Autodetected SCSI Jukebox.
3) Configure an Autodetected NDMP SCSI Jukebox.
4) Configure an SJI Jukebox.
5) Configure an STL Silo.

What kind of Jukebox are you configuring? [1] 2 These are the SCSI
Jukeboxes currently attached to your system:
1) /dev/scsi/changer/c6t0d0: Standard SCSI Jukebox, ADIC / FastStor 2
2) /dev/scsi/changer/c8t1d0: Standard SCSI Jukebox, ADIC / FastStor DLT

#reboot

Verify the jukebox after re-configuration

#/usr/sbin/nsr/nsrjb -j